Live Rosin Gummies, Grape
Lot CAM-RGG-2044
The full document is below, exactly as the laboratory issued it.
- ProductLive Rosin Gummies, Grape
- Lot/batchCAM-RGG-2044
- Certificate of analysisReport available
- Third-party labKCA Laboratories
- Laboratory
- KCA Laboratories
- Accreditation
- ISO/IEC 17025:2017 accredited quality system
- Batch
- CAM-RGG-2044
- Tested
Measured result
- Δ99.58 mg/unit
- CBN10.2 mg/unit
These are the figures the laboratory measured for this batch. The number printed on the package is the formulation target, and the two will differ slightly, that is normal.
The document
Page 1 of the laboratory’s certificate. The PDF has every page.
Open the certificateRead the full report as text
The laboratory’s report word for word, line by line, for screen readers and anyone who cannot open the PDF. The PDF is the original. If you would rather hear it, call (512) 850-4298 and we will read it to you or send it another way.
Page 1 of 6
KCA Laboratories, +1-833-KCA-LABS, Certificate of Analysis
232 North Plaza Drive, https://kcalabs.com
Nicholasville, KY 40356, KDA Lic.# P_0058, 1 of 6
CAM Gummies - Grape
Sample ID: SA-250807-66783, Client
Batch: CAM - RGG - 2044, Received: 08/07/2025, HH Harvest Co
Type: Finished Product - Ingestible, Completed: 09/04/2025, 249 Barnett Rd Suite 101
Matrix: Edible - Gummy, Medford, OR 97501
Unit Mass (g): 3.7468, USA
Summary
Test, Date Tested, Status
Cannabinoids, 08/19/2025, Tested
Heavy Metals, 09/04/2025, Tested
Microbials, 08/27/2025, Tested
Mycotoxins, 09/04/2025, Tested
Pesticides, 09/04/2025, Tested
Residual Solvents, 08/22/2025, Tested
0.256 %, 0.272 %, 0.536 %, Not Tested, Not Tested, Yes
Total Δ9-THC, CBN, Total Cannabinoids, Moisture Content, Foreign Matter, Internal Standard
Normalization
Cannabinoids by HPLC-PDA
Analyte, LOD, LOQ, Result, Result
(%), (%), (%), (mg/unit)
CBC, 0.00095, 0.00284, 0.00410, 0.154
CBCA, 0.00181, 0.00543, ND, ND
CBCV, 0.0006, 0.0018, ND, ND
CBD, 0.00081, 0.00242, ND, ND
CBDA, 0.00043, 0.0013, ND, ND
CBDV, 0.00061, 0.00182, ND, ND
CBDVA, 0.00021, 0.00063, ND, ND
CBG, 0.00057, 0.00172, 0.00340, 0.127
CBGA, 0.00049, 0.00147, ND, ND
CBL, 0.00112, 0.00335, ND, ND
CBLA, 0.00124, 0.00371, ND, ND
CBN, 0.00056, 0.00169, 0.272, 10.2
CBNA, 0.0006, 0.00181, ND, ND
CBT, 0.0018, 0.0054, ND, ND
Δ8-THC, 0.00104, 0.00312, ND, ND
Δ9-THC, 0.00076, 0.00227, 0.256, 9.58
Δ9-THCA, 0.00084, 0.00251, <LOQ, <LOQ
Δ9-THCV, 0.00069, 0.00206, <LOQ, <LOQ
Δ9-THCVA, 0.00062, 0.00186, ND, ND
Total Δ9-THC, 0.256, 9.58
Total, 0.536, 20.1
ND = Not Detected; NT = Not Tested; LOD = Limit of Detection; LOQ = Limit of Quantitation; RL = Reporting Limit; Δ = Delta; Total Δ9-THC = Δ9-THCA * 0.877 + Δ9-THC; Total CBD = CBDA * 0.877 + CBD;
Generated By: Ryan Bellone, Tested By: Nicholas Howard
Commercial Director, Scientist
Date: 09/04/2025, Date: 08/19/2025
This product or substance has been tested by KCA Laboratories using validated testing methodologies and an ISO/IEC 17025:2017 accredited quality system. Values reported relate only to the product or substance
tested. The reported result is based on a sample weight. Unless otherwise stated, results of tests performed on all quality control samples met criteria for acceptance established by KCA Laboratories. KCA
Laboratories makes no claims as to the efficacy, safety or other risks associated with any detected or non-detected amounts of any substances reported herein. This Certificate of Analysis shall not be reproduced
except in full, without the written approval of KCA Laboratories. KCA Laboratories can provide measurement uncertainty upon request.
Page 2 of 6
Heavy Metals by ICP-MS
Analyte, LOD (ppm), LOQ (ppm), Result (ppm)
Arsenic, 0.002, 0.02, ND
Cadmium, 0.001, 0.02, ND
Lead, 0.002, 0.02, ND
Mercury, 0.012, 0.05, ND
ND = Not Detected; NT = Not Tested; LOD = Limit of Detection; LOQ = Limit of Quantitation; P = Pass; F = Fail; RL = Reporting Limit; Values over action limits may be estimates
Generated By: Ryan Bellone, Tested By: Chris Farman
Commercial Director, Scientist
Date: 09/04/2025, Date: 09/04/2025
This product or substance has been tested by KCA Laboratories using validated testing methodologies and an ISO/IEC 17025:2017 accredited quality system. Values reported relate only to the product or substance
tested. The reported result is based on a sample weight. Unless otherwise stated, results of tests performed on all quality control samples met criteria for acceptance established by KCA Laboratories. KCA
Laboratories makes no claims as to the efficacy, safety or other risks associated with any detected or non-detected amounts of any substances reported herein. This Certificate of Analysis shall not be reproduced
except in full, without the written approval of KCA Laboratories. KCA Laboratories can provide measurement uncertainty upon request.
Page 3 of 6
Pesticides by LC-MS/MS and GC-MS/MS
Analyte, LOD, LOQ, Result, Analyte, LOD, LOQ, Result
(ppb), (ppb), (ppb), (ppb), (ppb), (ppb)
Abamectin, 30, 100, ND, Hexythiazox, 30, 100, ND
Acephate, 30, 100, ND, Imazalil, 30, 100, ND
Acetamiprid, 30, 100, ND, Imidacloprid, 30, 100, ND
Aldicarb, 30, 100, ND, Kresoxim methyl, 30, 100, ND
Azoxystrobin, 30, 100, ND, Malathion, 30, 100, ND
Bifenazate, 30, 100, ND, Metalaxyl, 30, 100, ND
Bifenthrin, 30, 100, ND, Methiocarb, 30, 100, ND
Boscalid, 30, 100, ND, Methomyl, 30, 100, ND
Carbaryl, 30, 100, ND, Mevinphos, 30, 100, ND
Carbofuran, 30, 100, ND, Myclobutanil, 30, 100, ND
Chloranthraniliprole, 30, 100, ND, Naled, 30, 100, ND
Chlorfenapyr, 30, 100, ND, Oxamyl, 30, 100, ND
Chlorpyrifos, 30, 100, ND, Paclobutrazol, 30, 100, ND
Clofentezine, 30, 100, ND, Permethrin, 30, 100, ND
Coumaphos, 30, 100, ND, Phosmet, 30, 100, ND
Daminozide, 30, 100, ND, Piperonyl Butoxide, 30, 100, ND
Diazinon, 30, 100, ND, Prallethrin, 30, 100, ND
Dichlorvos, 30, 100, ND, Propiconazole, 30, 100, ND
Dimethoate, 30, 100, ND, Propoxur, 30, 100, ND
Dimethomorph, 30, 100, ND, Pyrethrins, 30, 100, ND
Ethoprophos, 30, 100, ND, Pyridaben, 30, 100, ND
Etofenprox, 30, 100, ND, Spinetoram, 30, 100, ND
Etoxazole, 30, 100, ND, Spinosad, 30, 100, ND
Fenhexamid, 30, 100, ND, Spirotetramat, 30, 100, ND
Fenoxycarb, 30, 100, ND, Spiroxamine, 30, 100, ND
Fenpyroximate, 30, 100, ND, Tebuconazole, 30, 100, ND
Fipronil, 30, 100, ND, Thiacloprid, 30, 100, ND
Flonicamid, 30, 100, ND, Thiamethoxam, 30, 100, ND
Fludioxonil, 30, 100, ND, Trifloxystrobin, 30, 100, ND
ND = Not Detected; NT = Not Tested; LOD = Limit of Detection; LOQ = Limit of Quantitation; P = Pass; F = Fail; RL = Reporting Limit; Values over action limits may be estimates
Generated By: Ryan Bellone, Tested By: Jasper van Heemst
Commercial Director, Principal Scientist
Date: 09/04/2025, Date: 09/04/2025
This product or substance has been tested by KCA Laboratories using validated testing methodologies and an ISO/IEC 17025:2017 accredited quality system. Values reported relate only to the product or substance
tested. The reported result is based on a sample weight. Unless otherwise stated, results of tests performed on all quality control samples met criteria for acceptance established by KCA Laboratories. KCA
Laboratories makes no claims as to the efficacy, safety or other risks associated with any detected or non-detected amounts of any substances reported herein. This Certificate of Analysis shall not be reproduced
except in full, without the written approval of KCA Laboratories. KCA Laboratories can provide measurement uncertainty upon request.
Page 4 of 6
Mycotoxins by LC-MS/MS
Analyte, LOD (ppb), LOQ (ppb), Result (ppb)
B1, 1, 5, ND
B2, 1, 5, ND
G1, 1, 5, ND
G2, 1, 5, ND
Ochratoxin A, 1, 5, ND
ND = Not Detected; NT = Not Tested; LOD = Limit of Detection; LOQ = Limit of Quantitation; P = Pass; F = Fail; RL = Reporting Limit; Values over action limits may be estimates
Generated By: Ryan Bellone, Tested By: Jasper van Heemst
Commercial Director, Principal Scientist
Date: 09/04/2025, Date: 09/04/2025
This product or substance has been tested by KCA Laboratories using validated testing methodologies and an ISO/IEC 17025:2017 accredited quality system. Values reported relate only to the product or substance
tested. The reported result is based on a sample weight. Unless otherwise stated, results of tests performed on all quality control samples met criteria for acceptance established by KCA Laboratories. KCA
Laboratories makes no claims as to the efficacy, safety or other risks associated with any detected or non-detected amounts of any substances reported herein. This Certificate of Analysis shall not be reproduced
except in full, without the written approval of KCA Laboratories. KCA Laboratories can provide measurement uncertainty upon request.
Page 5 of 6
Microbials by PCR and Plating
Analyte, LOD (CFU/g), Result (CFU/g), Result (Qualitative)
Total aerobic count, 10, ND
Total coliforms, 10, ND
Generic E. coli, 10, ND
Salmonella spp., 1, Not Detected per 1 gram
Shiga-toxin producing E. coli (STEC), 1, Not Detected per 1 gram
ND = Not Detected; NT = Not Tested; LOD = Limit of Detection; LOQ = Limit of Quantitation; CFU = Colony Forming Units; P = Pass; F = Fail; RL = Reporting Limit
Generated By: Ryan Bellone, Tested By: Sara Cook
Commercial Director, Laboratory Technician
Date: 09/04/2025, Date: 08/27/2025
This product or substance has been tested by KCA Laboratories using validated testing methodologies and an ISO/IEC 17025:2017 accredited quality system. Values reported relate only to the product or substance
tested. The reported result is based on a sample weight. Unless otherwise stated, results of tests performed on all quality control samples met criteria for acceptance established by KCA Laboratories. KCA
Laboratories makes no claims as to the efficacy, safety or other risks associated with any detected or non-detected amounts of any substances reported herein. This Certificate of Analysis shall not be reproduced
except in full, without the written approval of KCA Laboratories. KCA Laboratories can provide measurement uncertainty upon request.
Page 6 of 6
Residual Solvents by HS-GC-MS
Analyte, LOD, LOQ, Result, Analyte, LOD, LOQ, Result
(ppm), (ppm), (ppm), (ppm), (ppm), (ppm)
Acetone, 167, 500, ND, Ethylene Oxide, 0.5, 1, ND
Acetonitrile, 14, 41, ND, Heptane, 167, 500, ND
Benzene, 0.5, 1, ND, n-Hexane, 10, 29, ND
Butane, 167, 500, ND, Isobutane, 167, 500, ND
1-Butanol, 167, 500, ND, Isopropyl Acetate, 167, 500, ND
2-Butanol, 167, 500, ND, Isopropyl Alcohol, 167, 500, ND
2-Butanone, 167, 500, ND, Isopropylbenzene, 167, 500, ND
Chloroform, 2, 6, ND, Methanol, 100, 300, ND
Cyclohexane, 129, 388, ND, 2-Methylbutane, 10, 29, ND
1,2-Dichloroethane, 0.5, 1, ND, Methylene Chloride, 20, 60, ND
1,2-Dimethoxyethane, 4, 10, ND, 2-Methylpentane, 10, 29, ND
Dimethyl Sulfoxide, 167, 500, ND, 3-Methylpentane, 10, 29, ND
N,N-Dimethylacetamide, 37, 109, ND, n-Pentane, 167, 500, ND
2,2-Dimethylbutane, 10, 29, ND, 1-Pentanol, 167, 500, ND
2,3-Dimethylbutane, 10, 29, ND, n-Propane, 167, 500, ND
N,N-Dimethylformamide, 30, 88, ND, 1-Propanol, 167, 500, ND
2,2-Dimethylpropane, 167, 500, ND, Pyridine, 7, 20, ND
1,4-Dioxane, 13, 38, ND, Tetrahydrofuran, 24, 72, ND
Ethanol, 167, 500, ND, Toluene, 30, 89, ND
2-Ethoxyethanol, 6, 16, ND, Trichloroethylene, 3, 8, ND
Ethyl Acetate, 167, 500, ND, Xylenes (o-, m-, and p-), 73, 217, ND
Ethyl Ether, 167, 500, ND
Ethylbenzene, 3, 7, ND
ND = Not Detected; NT = Not Tested; LOD = Limit of Detection; LOQ = Limit of Quantitation; P = Pass; F = Fail; RL = Reporting Limit; Values over action limits may be estimates
Generated By: Ryan Bellone, Tested By: Kelsey Rogers
Commercial Director, Scientist
Date: 09/04/2025, Date: 08/22/2025
This product or substance has been tested by KCA Laboratories using validated testing methodologies and an ISO/IEC 17025:2017 accredited quality system. Values reported relate only to the product or substance
tested. The reported result is based on a sample weight. Unless otherwise stated, results of tests performed on all quality control samples met criteria for acceptance established by KCA Laboratories. KCA
Laboratories makes no claims as to the efficacy, safety or other risks associated with any detected or non-detected amounts of any substances reported herein. This Certificate of Analysis shall not be reproduced
except in full, without the written approval of KCA Laboratories. KCA Laboratories can provide measurement uncertainty upon request.